45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater

Product Details
Customization: Available
Certification: SASO, RoHS, CCC, ISO9001, CE, ERP
Working Medium: R410A

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, QC 080000
OEM/ODM Availability
Yes
  • 45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater
  • 45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater
  • 45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater
  • 45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater
  • 45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater
  • 45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater
Find Similar Products
  • Overview
  • Technical
  • Project Cases
  • Certifications
  • Company Profile
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
powerSTAR45M
Heat Source Type
Air Source Heat Pump
Heating Capacity
45kW
ERP
A++
Power Supply
400V/50Hz/3pH
Fan type
EC Fan
Unit Type
DC Inverter+EVI
Sound Power Level
66
Refrigerant
R410A
Net Weight
300kG
WIFI Module
Yes
Compressor
Mitsubishi
Transport Package
Plywood
Specification
45kW Heating Capacity
Trademark
Amitime
Origin
China
HS Code
8418612090
Production Capacity
600PCS/Day

Product Description


R410A PowerSTAR series

By using the latest inveter+EVI technology, powerSTAR series is designed as a high energy-efficient and stable heating solution, with wide heating capacity from 25kW to 90kW. Not only with inverter compressor, it can adjust working speed according to heating demand automatically, to optimize the efficiency of the whole system, but also with EVI technology, it can always provide stable heating output, to minimize your energy consumption in cold winter. powerSTAR is a simple but powerful solution, which meets heating, cooling and stabel hot water demand for commercial applications, such as apartments, hotels, and schools, etc.
 

Technical

 

Model no.   powerSTAR25M powerSTAR30M powerSTAR45M powerSTAR90M
IP rating IPXX IPX4 IPX4 IPX4 IPX4
Power supply
Power supply - Outdoor unit Outdoor unit V / Hz / Ph 400V/50Hz/3ph 400V/50Hz/3ph 400V/50Hz/3Ph 400V/50Hz/3Ph
Fuse Outdoor unit A 3p/25A/C 3p/25A/C 3p/40A/C 3p/80A/C
Performance 
Min/max heating capacity (1)  kW 7.9~25.1 15.2/28.7 13.7~43.7 27.4~89.6
El. heating power input min/max (1)  W 2564~6172 3467/7488 3325~12077 6650~24254
C.O.P min/max (1)  W/W 3.07~4.41 3.83/4.43 3.62~4.42 3.68~4.50
Min/max heating capacity (2)    kW 9.9~24.8 12.2/29.4 13.6~43.2 28.2~89.5
El. heating power input min/max (2)  W 3141~7625 3769/9035 4156~14308 8212~28300
C.O.P min/max (2)  W/W 3.16~3.43 3.26/3.43 2.99~3.38 3.16~3.48
SCOP - Average climate, low temperature  W 4.04 4.06 4.12 4.2
Energy class     A++ A++ A++ A++
Min/max cooling capacity (3)  kW 10.6~21.5 15.2/26.8 17.7~32.0 36.4~66.0
El. coolimg power input min/max (3)  W 2528~7678 3253/8765 3491~11771 6982~23742
E.E.R. min/max (3)  W/W 2.81~4.20 3.06/4.68 2.72~5.09 2.8~5.19
Min/max cooling capacity (4)    (A35/W7) kW 7.1~18.1 7.3/21.2 11.2~29.9 23.4~61.2
El. cooling power input min/max (4)  W 2570~6746 3121/7960 3529~11640 6.88~23450
E.E.R.  min/max (4)  W/W 2.46/3.04 2.33/2.84 2.57~3.3 2.61~3.4
Min/max ambient working temp. in heating mode °C -30-55 -30-55 -30-55 -30-55
Min/max ambient working temp. in cooling mode °C 15-55 15-55 15-55 15-55
Max flow temp. in heating mode °C 60 60 60 60
Min flow temp. in heating mode °C 20 20 20 20
Min flow temp. in cooling mode °C 7 7 7 7
Sound power level  Outdoor unit dB (A) 62 62 66 69
Indoor unit  dB (A) / / / /
Components
Compressor heater   W 30 30 30 30*2
Fan Yes pcs 2 2 1 2
Airflow m³/h 5250*2 5250*2 13500 13500*2
Rated power W 93*2 93*2 800 800*2
Blade diameter mm 552*2 552*2 760 760*2
Tube in shell heat exchange Water press. drop kPa 50 60 80 100
Piping connection Inch 1 1/2''Inner gorve 1 1/2''Inner gorve 2" Inner gorve DN65 Flange
Refrigerant  type / R410A R410A R410A R410A
charge kg 4.4kg 5.2kg 8kg 8kg*2
Compressor   type / Inverter+EVI Inverter+EVI Inverter+EVI Inverter+EVI
Compressor oil type FVC68S FVC68S FVC68D FVC68D
Comp. oil volume L 1.9L 1.9L 2.3L 2.3L*2
Compressor heater W 30W 30W 30W 30W*2
Compressor brand and type    Panasonic, twin rotary Panasonic, twin rotary Mitsubishi Electric
scroll
Mitsubishi Electric
scroll
Hydraulics
Minimum water flow m³/h - l/s 2.8m³/h 2.8m³/h 5m³/h 10m³/h
Nominal water flow m³/h 4.3m³/h 5.2m³/h 8m³/h 16m³/h
Hydraulic connections Size 1 1/2''Inner gorve 1 1/2''Inner gorve 2" Inner gorve DN65 Flange
Dimensions and weight
Net Dimensions (L x D x H) Outdoor unit mm 1215*460*1445 1295*460*1445 1010*1160*1650 2160*1200*1650
Indoor unit  mm 385*476*150 385*476*150 385*476*150 385*476*150
Brutto Dimensions (L x D x H) Outdoor unit mm 1265*480*1585 1325*480*1585 1030*1180*1750 2180*1220*1750
Indoor unit  mm 400*490*180 400*490*180 400*490*180 400*490*180
Net weight Outdoor unit kg 165 180 300 600
Indoor unit  kg 9 9 9 9
Brutto weight Outdoor unit kg 185 200 370 680
Indoor unit  kg 10 10 10 10
Included with the unit
Temperature sensors type 5K,B=3470
50K,B=3950
5K,B=3470
50K,B=3950
5K,B=3470 5K,B=3470
WiFI module Yes / No Yes  Yes  Yes  Yes 
Communication cable m 20 20 20 20
Note:
(1) Heating condition: water inlet/outlet temperature: 30 °C/35°C, Ambient temperature: DB 7 °C /WB 6 °C;
(2) Heating condition: water inlet/outlet temperature: 40°C/45°C, Ambient temperature: DB 7 °C /WB 6 °C;
(3) Cooling condition: water inlet/outlet temperature: 23 °C/18°C, Ambient temperature: DB 35 °C /WB 24 °C;
(4) Cooling condition: water inlet/outlet temperature: 12°C/7°C, Ambient temperature: DB 35 °C /WB 24 °C.

45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater
45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater

 

Project Cases

 

45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater

Certifications


45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater

Company Profile

 

45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater

Exhibition

 

45kW R410A DC Inverter A++ Air Source Commercial Heat Pump heater

FAQ

Q: Do you provide OEM & ODM?
A: Yes. We can design products and make logos, labels, cartons, user manuals etc. according to our customer's demand.

Q: What's your MOQ?
A: For official orders, our MOQ is a full container load of 40 feet contaienr.

Q: What's your lead time for orders?
A: Usually 30-35 days. For order of big quantity, to be discussed.

Q: What's your production capacity?
A: We have in total 10 production lines in our factory in Zhongshan now, the production capacity is around 1000 pcs/day.
A new base in Shunde will get ready in 2023 and our production capacity will increase to around 2500 pcs/day.

Q: How can I get the price?
A: We usually quote within 24 hours after we get your inquiry.

Q: What's the payment terms?
A: By T/T, 30% deposit to confirm the order, and the balance to be done before shipment.

Q: How long is your warranty?
A: One year warranty for complete machine, three years warranty for compressor, and long-term technical support.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier