R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater

Product Details
Customization: Available
Certification: RoHS, CCC, ISO9001, CE, ERP
Working Medium: R32

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, QC 080000
OEM/ODM Availability
Yes
  • R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater
  • R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater
  • R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater
  • R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater
  • R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater
  • R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater
Find Similar Products
  • Overview
  • Technical
  • Project Cases
  • Certifications
  • Company Profile
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
heatSTAR+9A-S
Heat Source Type
Air Source Heat Pump
Heating Capacity
4.3/9.2kW
ERP
A+++
Power Supply
220-240V/50Hz/1pH
Fan
DC
Other Model
6kW/9kW/12kW/15kW/19kW
Compressor Type
DC Inverter
Sound Power Level
52
Refrigerant
R32
WIFI Module
Yes
Compressor
Mitsubishi
Heat Exchanger
SWEP
Communication Protocal
Modbus
Transport Package
Carton Box and Wooden Pallet
Specification
9kW
Trademark
Amitime
Origin
China
HS Code
8418612090
Production Capacity
600PCS/Day

Product Description

 
R32 HeatSTAR series- All-in-One split
 
All In One System: are split systems combining a water tank in its indoor section. This structure minimizes the installation of the water tank in the house.

Technical

Model   heatSTAR+6A-S heatSTAR+9A-S heatSTAR+12A-S heatSTAR+15A-S heatSTAR+19A-S
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 - R32 380-420/50/3 - R32
Max. Heating Capacity (1) kW 6.5 9.2 11.6 15.5 18.5
C.O.P (1) W/W 4.7 4.48 4.3 4.6 4.38
Heating Capacity Min./Max.(1) kW 3.5 / 6.5 4.3/9.2 5.5 / 11.6 7.3/15.5 9.1/18.5
Heating Power Input Min./Max.(1) W 738/ 1652 885/2055 1107 / 2683 1600/3300 1900/4200
C.O.P Min./Max.(1) W/W 4.5 / 4.81 4.48/4.88 4.3 / 4.9 4.5/5.0 4.38/4.79
Max. Heating Capacity(2) kW 5.9 8.6 11.2 14.4 18.2
C.O.P (2) W/W 3.1 3.46 3.4 3.5 3.58
Heating Capacity Min./Max.(2) kW 2.3 / 5.9 3.9/8.6 4.9 / 11.2 6.6/14.4 8.5/18.2
Heating power input Min./Max.(2) W 909/ 1917 1120/2510 1401 / 3263 1900/4100 2300/5000
C.O.P Min./Max.(2) W/W 2.6/3.1 3.46/3.66 3.4/ 3.6 3.5/3.7 3.58/3.72
Max. Cooling Capacity (3) kW 7.41 9.5 9.8 18.5 19.3
E.E.R (3) W/W 4.1 4.31 3.9 3.7 3.05
Cooling Capacity Min./Max.(3) kW 6.22/7.41 8.48/9.5 7.0/ 9.8 7.2/18.5 16/19.3
Cooling Power Input Min./Max.(3) W 1374/1806 1860/2200 1728/ 2510 1400/5000 4700/6300
E.E.R Min./Max.(3) W/W 4.1/4.5 4.31/4.56 4.05 / 3.9 3.7/5.1 3.05/3.41
Max. Cooling Capacity (4) kW 4.25 7.2 8.5 13 15.8
E.E.R (4) W/W 2.7 2.8 2.7 3.0  2.89
Cooling Capacity Min./Max.(4) kW 3.6/4.3 5.45/6.95 4.9 / 8.5 10.3/13 12.3/15.8
Cooling Power Input Min./Max.(4) W 1308/1680 1768/2324 1358 / 2987 3200/4300 4000/5400
E.E.R Min./Max.(4) W/W 2.5/2.7 3.0/3.14 2.87 / 3.7 3.0/3.2 2.89/3.04
Circuit Breaker   A 16 25 25 25 25
Workable Ambient Temperature Range ºC -25~43
Min. System Water Temperature (Heating / Cooling) ºC 20 / 7
Min. Floor Area for installation, operation and storage m2 0.8 1.9 3.1 6.2 6.2
Min. Area of Pipe-work m2 0.8 1.9 3.1 6.2 6.2
Max. Operation High Pressure MPa 4.2
Max. Operation Low Pressure MPa 1.2
Compressor Type - Quantity/System   Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1
Refrigerant Type / Amount - / kg R32 / 1kg R32 / 1.6kg R32 / 1.8kg R32 / 2.6kg R32 / 3kg
Fan Quantity   1 1 1 2 2
Airflow m3/h 2500 3150 3150 6200 6200
Rated power W 35 45 45 90 90
Noise Level Indoor/Outdoor dB(A) 44/52 45/53 45/52 40/57 44/57
Water Side Heat Exchanger Type   Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
Water Pressure Drop kPa 26 26 26 26 26
Piping Connection Inch G1" G1" G1" G5/4" G5/4"
Allowable Water Flow Min./Rated./Max. L/S 0.21/0.29/0.35 0.3/0.43/0.56 0.4/0.57/0.74 0.5/0.72/0.93 0.64/0.9/1.2
Net Dimension(L×D×H) Indoor Unit-250L mm 600x710x1720 600x710x1720 600x710x1720 600x730x1720 600x730x1720
Outdoor Unit mm 1010x370x700 1165x370x845 1165x370x845 1085x400x1450 1085x400x1450
Net Weight Indoor Unit-250L Kg 139 141 141 145 147
Outdoor Unit Kg 59 69 75 120 130

Note:
(1) Heating condition: water inlet/outlet temperature: 30ºC/35ºC, Ambient temperature: DB 7ºC/WB 6ºC;
(2) Heating condition: water inlet/outlet temperature: 40ºC/45ºC, Ambient temperature: DB 7ºC/WB 6ºC;
(3) Cooling condition: water inlet/outlet temperature: 23ºC/18ºC, Ambient temperature: DB 35ºC/WB 24ºC;
(4) Cooling condition: water inlet/outlet temperature: 12ºC/7ºC, Ambient temperature: DB 35ºC/WB 24ºC;
(5) The specifications are subject to change without prior notice. For actual specifications of unit, please refer to the stickers on the unit.
 
R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater
R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heaterR32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heaterR32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater

Project Cases

 

R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater

Certifications

R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater

Company Profile

 

R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater

Exhibition

 

R32 split Heat Pump High Efficiency Heating &Cooling&Dhw water heater

FAQ

Q: Do you provide OEM & ODM?
A: Yes. We can design products and make logos, labels, cartons, user manuals etc. according to our customer's demand.

Q: What's your MOQ?
A: For official orders, our MOQ is a full container load of 40 feet contaienr.

Q: What's your lead time for orders?
A: Usually 30-35 days. For order of big quantity, to be discussed.

Q: What's your production capacity?
A: We have in total 10 production lines in our factory in Zhongshan now, the production capacity is around 1000 pcs/day.
A new base in Shunde will get ready in 2023 and our production capacity will increase to around 2500 pcs/day.

Q: How can I get the price?
A: We usually quote within 24 hours after we get your inquiry.

Q: What's the payment terms?
A: By T/T, 30% deposit to confirm the order, and the balance to be done before shipment.

Q: How long is your warranty?
A: One year warranty for complete machine, three years warranty for compressor, and long-term technical support.

 