19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump

Product Details
Customization: Available
Certification: SASO, RoHS, CB, CCC, ISO9001, CE, ERP
Working Medium: R290

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, QC 080000
OEM/ODM Availability
Yes
  • 19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
  • 19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
  • 19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
  • 19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
  • 19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
  • 19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
Find Similar Products
  • Overview
  • Technical
  • Project Cases
  • Certifications
  • Company Profile
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
EcoSTAR15M
Heating Capacity
5.6/16.5kW
ERP
A+++
Power Supply
380-415/50/3
Noise Level (sound power)
37/56
Specification
15kW
Trademark
Amitime
Origin
China
HS Code
84186
Production Capacity
1000PCS/Day

Product Description


R290 EcoSTAR series- Standard Monoblock

Thanks to the use of R290, Amitime heatSTAR+ series (R290) is now not only the best solution for new building, but also possible to fit the retrofit market by lifting up maximum heating temperature to 70C. With good performance in this water temeprature rante, air to water heat pump unit is now possible to be used to replace the old gas/oil boiler without changing the existing heating distribution system, even has old radiators inside.

Amitime's EcoSTAR system has been developed with the idea in mind for maximum possible energy saving, through its ultra high scope rating and quiet operation. Latest development in DC inverter technologies and their application in various internal components including compressor, fan, and water pump, has been the major player in the success of our EcoSTAR line.
 

Technical

 

Model   EcoSTAR04M EcoSTAR06M EcoSTAR09M EcoSTAR12M EcoSTAR15M
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 - R290 220-240/50/1 - R290 220-240/50/1 - R290 220-240/50/1 - R290 380-415/50/3 - R290
Max. Heating Capacity (1) kW 6.20  6.70  9.5 12.0  16.5
C.O.P (1) W/W 4.57 4.44 4.55 3.92  3.98
Heating Capacity Min./Max.(1) kW 2.5/ 6.2 3.1/ 6.7 3.1 / 9.5 3.8 / 12 5.6/16.5
Heating Power Input Min./Max.(1) W 500 / 1360 680/ 1500 585/ 2089 900 / 3065 1120/4170
C.O.P Min./Max.(1) W/W 4.57/4.99 4.44/ 4.83 4.55 / 5.1 3.92/ 4.8 3.98/5.05
Max. Heating Capacity(2) kW 5.8 6.5 9 11 15.5
C.O.P (2) W/W 3.68 3.62 3.75 3.28 3.25
Heating Capacity Min./Max.(2) kW 2.2 /5.8 3.0 /6.5 2.7 /9.0 3.7/ 11.0 5.3/15.5
Heating power input Min./Max.(2) W 600 /1600 600 /1800 725 / 2400 1100 / 3350 1370/4770
C.O.P Min./Max.(2) W/W 3.6 / 3.85 3.62 / 3.86 3.75 / 4.0 3.28/3.7 3.25/3.85
Max. Cooling Capacity (3) kW 5.4 5.5 8 10.2  13.2
E.E.R (3) W/W 4.11 4.13 3.8 3.6 3.65
Cooling Capacity Min./Max.(3) kW 2.8 / 5.4 2.4/ 5.4 2.4 / 8.0 5.0/10.2 6.9/13.2
Cooling Power Input Min./Max.(3) W 500 / 1300 510 / 1300 765 / 2100 1400/2840 1540/3650
E.E.R Min./Max.(3) W/W 4.11/ 5.39 4.1/ 4.23 3.80 / 4.0 3.6/3.9 3.65/4.4
Max. Cooling Capacity (4) kW 3.5 3.7 6 7.5 10.1
E.E.R (4) W/W 2.89  2.86  2.90  2.75 2.85
Cooling Capacity Min./Max.(4) kW 0.8 /3.5 1.3 /3.7 1.8 /6.0 3.6/7.5 4.8/10.1
Cooling Power Input Min./Max.(4) W 500 /1200 470 /1260 720 /1945 1330/2740 1550/3540
E.E.R Min./Max.(4) W/W 1.54/ 2.97 2.63/ 2.95 2.9 / 3.05 2.75/2.90 2.85/3.05
Circuit Breaker A 16 16 16 32 25
Workable Ambient Temperature Range ºC -25~45 -25~45 -25~45 -25~45 -25~45
Max. System Water Temperature (Heating / Cooling) ºC 70/20 70/20 70/20 70/20 70/20
Min. System Water Temperature (Heating / Cooling) ºC 20 / 7 20 / 7 20 / 7 20 / 7 20 / 7
Max. Operation High Pressure MPa 3.10 3.10 3.10 3.10 3.10
Max. Operation Low Pressure MPa 0.82 0.82 0.82 0.82 0.82
Compressor Type - Quantity/System   Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1 Twin Rotary - 1
Refrigerant Type / Amount - / kg R290 / 0.45kg R290 / 0.6kg R290 / 0.7kg R290 /0.9kg R290 / 1.5kg
Fan Quantity   1 1 1 1 2
Airflow m3/h 2850 3150 3150 3300 6300
Rated power W 62 62 62 62 124
Noise Level (sound power) Indoor/Outdoor dB(A) -/50 33/54 33/54  34/56 37/56
Water Side Heat Exchanger Type   Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
Water Pressure Drop kPa 23 23 23 23 23
Piping Connection Inch G1" G1" G1" G1" G1-1/4"
Allowable Water Flow Min./Rated./Max. L/S 0.21/0.29/0.35 0.21/0.29/0.35 0.26/0.39/0.46 0.34/0.57/0.68 0.5/0.72/0.86
Net Dimension(L×D×H) Indoor Unit mm 570x550x260 570x550x260 570x550x260 570x550x260 570x550x260
Net Dimension(L×D×H) Outdoor Unit mm 1010x370x700 1165x370x850 1165x370x850 1165x370x950 1085x390x1450
Net Weight Indoor Unit kg 25 25 25 25 25
Net Weight Outdoor Unit kg 73 90 98 110 145
Note:
(1) Heating condition: water inlet/outlet temperature: 30 °C/35°C, Ambient temperature: DB 7 °C /WB 6 °C;
(2) Heating condition: water inlet/outlet temperature: 40°C/45°C, Ambient temperature: DB 7 °C /WB 6 °C;
(3) Cooling condition: water inlet/outlet temperature: 23 °C/18°C, Ambient temperature: DB 35 °C /WB 24 °C;
(4) Cooling condition: water inlet/outlet temperature: 12°C/7°C, Ambient temperature: DB 35 °C /WB 24 °C; (5) The specifications are subject to change without prior notice. For actual specifications of unit, please refer to the stickers on the unit.

19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump
 

Project Cases

 

19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump

Certifications

19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump

Company Profile

 

19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump

Exhibition

 

19kW R290 DC Hybrid Inverter Central Air Conditioner Water Heat Pump

FAQ

Q: Do you provide OEM & ODM?
A: Yes. We can design products and make logos, labels, cartons, user manuals etc. according to our customer's demand.

Q: What's your MOQ?
A: For official orders, our MOQ is a full container load of 40 feet contaienr.

Q: What's your lead time for orders?
A: Usually 30-35 days. For order of big quantity, to be discussed.

Q: What's your production capacity?
A: We have in total 10 production lines in our factory in Zhongshan now, the production capacity is around 1000 pcs/day.
A new base in Shunde will get ready in 2023 and our production capacity will increase to around 2500 pcs/day.

Q: How can I get the price?
A: We usually quote within 24 hours after we get your inquiry.

Q: What's the payment terms?
A: By T/T, 30% deposit to confirm the order, and the balance to be done before shipment.

Q: How long is your warranty?
A: One year warranty for complete machine, three years warranty for compressor, and long-term technical support.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier