• Outes/OEM R32 full monoblock Water Source Heat Pump heater
  • Outes/OEM R32 full monoblock Water Source Heat Pump heater
  • Outes/OEM R32 full monoblock Water Source Heat Pump heater
  • Outes/OEM R32 full monoblock Water Source Heat Pump heater
  • Outes/OEM R32 full monoblock Water Source Heat Pump heater
  • Outes/OEM R32 full monoblock Water Source Heat Pump heater

Outes/OEM R32 full monoblock Water Source Heat Pump heater

Certification: RoHS, CCC, ISO9001, CE
Heat Source Type: Air Source Heat Pump
Heating Capacity: 12kW
Power Supply: 220-240V/50Hz/1pH
Fan: DC Motor
Compressor Type: DC Inverter
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Technical
  • Project Cases
  • Certifications
  • Company Profile
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
HeatLITE12
Sound Power Level
53
Refrigerant
R32
Net Weight
82kg
WIFI Module
Yes
Compressor
Rotary
Transport Package
Carton Box and Wooden Pallet
Specification
12kW
Trademark
Amitime
Origin
China
HS Code
8418612090
Production Capacity
600PCS/Day

Product Description


R32 full monoblock unit
heatLITE-DC Inverter Air to Water Heat Pump

Amitime's heatLITE system has been developed with the idea in mind for maximum possible energy savings, through its ultra high scop rating and quiet operation. Latest development in DC inverter technologies and their application in various intemal componentsincluding compressor, fan, and water pump, has been the major player in the success of our heatLITE line.
 

Technical

 

Model   HeatLITE06 HeatLITE09 HeatLITE12 HeatLITE15 HeatLITE15T HeatLITE19
IP rating IPXX IPX4
Power supply
Power supply - Outdoor unit Outdoor unit V / Hz / Ph 220~240V/50Hz/1Ph 220~240V/50Hz/1Ph 220~240V/50Hz/1Ph 220~240V/50Hz/1Ph 380~400V/50Hz/3Ph 220~240V/50Hz/1Ph
Fuse Outdoor unit A 1p/ A/C 1p/ A/C 1p/ A/C 1p/ A/C 3p/ A/C 1p/ A/C
Performance       
Min/max heating capacity (1)  kW 3.3~7.2 5.0~9.7 5.9~11.9 5.9~16.4 5.9~16.4 6.6~18.8
El. heating power input min/max (1)  KW 0.7~1.6 1.0~2.4 1.3~2.9 1.25~3.7 1.25~3.7 1.3~4.6
C.O.P min/max (1)  W/W 4.26~ 4.87 4.01~4.57 4.05~4.67 4.3~4.7 4.3~4.7 4.03~5.01
Min/max heating capacity (2)    kW 3.1~6.9 4.2~8.9 6~11.5 4.4~15.8 4.4~15.8 6.1~18.4
El. heating power input min/max (2)  KW 0.9~1.9 1.3~2.9 1.6~3.6 1.64~4.5 1.64~4.5 1.7~5.6
C.O.P min/max (2)  W/W 3.41~3.78 3.03~3.4 3.19~3.66 2.68~3.5 2.68~3.5 3.29~3.71
SCOP - Average climate, low temperature  W 4.66 4.62 4.57 4.81 4.81 4.62
Energy class     A+++
Min/max cooling capacity (3)  kW 3.1~7.1 4.2~9.1 5.1~12.2 7.5~16.9 7.5~16.9 5.5~19.2
El. coolimg power input min/max (3)  KW 0.82~1.9 1.2~2.9 1.34~3.4 1.34~4.0 1.34~4.0 1.3~5.0
E.E.R. min/max (3)  W/W 3.32~4.25 3.28~4.24 3.33~4.33 4.23~5.6 4.23~5.6 3.81~4.71
Min/max cooling capacity (4)    (A35/W7) kW 1.8~4.8 3.1~7.9 4.2~8.9 5.1~11.2 5.1~11.2 4.7~13.1
El. cooling power input min/max (4)  KW 0.66~2.54 1.1~3.2 1.6~3.1 1.4~3.6 1.4~3.6 1.5~4.6
E.E.R.  min/max (4)  W/W 2.54~2.84 2.38~2.83 2.61~3.22 3.06~3.6 3.06~3.6 2.89~3.25
Ambient temperature range heating °C -25~43
cooling °C 7~43
Outlet water temperature range °C 7~55
Sound power level 55ºC dB (A) 54 61 62 59 59 65
35ºC dB (A) 54 57 58 63 63 61
Components
Fan Yes pcs 1     2
Airflow m³/h 2500 3280 3280 6200 6200 6200
Rated power W 60 62 62 124 124 124
Blade diameter mm Φ455 Φ550 Φ550 Φ550 Φ550 Φ550
Plate heat exchanger Water press. drop kPa 22 25 26 30 30 30
Piping connection size 1'' Inner gorve 1-1/2" Inner gorve
Refrigerant  type / R32
charge kg 0.75 1.15 1.3 2.6 2.6 2.9
Compressor type / Twin Rotary
Hydraulics
Minimum water flow m³/h 0.5 0.8 1.03 1.29 1.29 1.64
Nominal water flow m³/h 1 1.6 2.06 2.58 2.58 3.27
Hydraulic connections size 1'' Inner gorve 1-1/4" Inner gorve
Dimensions and weight
Net Dimensions (Lx D x H) Outdoor unit mm 1015×380×700 1175×380×845 1175×380×845 1095×405×1440 1095×405×1440 1095×405×1440
Brutto Dimensions (L x D x H) Outdoor unit mm 1060×470×865 1230×470×1020 1230×470×1020 1150×470×1580 1150×470×1580 1150×470×1580
Net weight Outdoor unit kg 70 79 82 133 142 138
Brutto weight Outdoor unit kg 81 90 93 148 152 153
Included with the unit
WIFI  Yes / No Yes
Communication cable m 10

Outes/OEM R32 full monoblock Water Source Heat Pump heater
Outes/OEM R32 full monoblock Water Source Heat Pump heater
Outes/OEM R32 full monoblock Water Source Heat Pump heaterOutes/OEM R32 full monoblock Water Source Heat Pump heater
 

Project Cases

 

Outes/OEM R32 full monoblock Water Source Heat Pump heater

Certifications

Outes/OEM R32 full monoblock Water Source Heat Pump heater

Company Profile

 

Outes/OEM R32 full monoblock Water Source Heat Pump heater

Exhibition

 

Outes/OEM R32 full monoblock Water Source Heat Pump heater

FAQ

Q: Do you provide OEM & ODM?
A: Yes. We can design products and make logos, labels, cartons, user manuals etc. according to our customer's demand.

Q: What's your MOQ?
A: For official orders, our MOQ is a full container load of 40 feet contaienr.

Q: What's your lead time for orders?
A: Usually 30-35 days. For order of big quantity, to be discussed.

Q: What's your production capacity?
A: We have in total 10 production lines in our factory in Zhongshan now, the production capacity is around 1000 pcs/day.
A new base in Shunde will get ready in 2023 and our production capacity will increase to around 2500 pcs/day.

Q: How can I get the price?
A: We usually quote within 24 hours after we get your inquiry.

Q: What's the payment terms?
A: By T/T, 30% deposit to confirm the order, and the balance to be done before shipment.

Q: How long is your warranty?
A: One year warranty for complete machine, three years warranty for compressor, and long-term technical support.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, QC 080000
OEM/ODM Availability
Yes