heatSTAR-DC Inverter Air to Water Heat Pump
Amitime's heatSTAR system has been developed with the idea in mind for maximum possible energy savings, through its ultra high scop rating and quiet operation. Latest development in DC inverter technologies and their application in various intemal componentsincluding compressor, fan, and water pump, has been the major player in the success of our heatSTAR line.
Model |
|
AVH-06V1FBA |
AVH-09V1FBA |
AVH-12V1FBA |
AVH-15V4FBA |
AVH-19V4FBA |
Power supply |
|
|
|
|
|
|
|
Power Supply / Refrigerant |
V/Hz/Ph |
220-240/50/1 - R32 |
380-420/50/3 - R32 |
Performance |
|
|
|
|
|
|
|
Max. Heating Capacity (1) |
kW |
6.5 |
9.2 |
11.6 |
15.35 |
18.5 |
C.O.P (1) |
W/W |
4.61 |
4.38 |
4.3 |
4.78 |
4.47 |
Heating Capacity Min./Max.(1) |
kW |
3.5 / 6.5 |
4.3/9.2 |
5.5 / 11.6 |
6/15.35 |
9.2/18.5 |
Heating Power Input Min./Max.(1) |
W |
758 / 1410 |
927/2097 |
1107 / 2683 |
1222/3209 |
1834/4142 |
C.O.P Min./Max.(1) |
W/W |
4.5 / 4.7 |
4.38/4.71 |
4.3 / 4.9 |
4.78/5.06 |
4.47/5.01 |
Max. Heating Capacity(2) |
kW |
6 |
8.6 |
11.2 |
14.26 |
18.2 |
C.O.P (2) |
W/W |
3.46 |
3.37 |
3.45 |
3.64 |
3.6 |
Heating Capacity Min./Max.(2) |
kW |
3.15 / 6 |
3.9/8.6 |
4.9 / 11.2 |
5.6/14.26 |
8.5/18.2 |
Heating power input Min./Max.(2) |
W |
943 / 1732 |
1162/2550 |
1401 / 3263 |
1551/3913 |
2248/4998 |
C.O.P Min./Max.(2) |
W/W |
3.34 / 3.56 |
3.37/3.58 |
3.3 / 3.5 |
3.64/3.82 |
3.6/3.82 |
Max. Cooling Capacity (3) |
kW |
7.45 |
9.5 |
9.8 |
18.57 |
22.5 |
E.E.R (3) |
W/W |
4.05 |
4.23 |
3.9 |
3.78 |
3.58 |
Cooling Capacity Min./Max.(3) |
kW |
6.22/7.45 |
6.7/9.5 |
7.2 / 9.8 |
7.23/18.57 |
8.5/22.5 |
Cooling Power Input Min./Max.(3) |
W |
1400/1863 |
1679/2242 |
1791 / 2510 |
1334/4917 |
1660/6285 |
E.E.R Min./Max.(3) |
W/W |
4.05/4.45 |
4.0/4.6 |
4.0 / 3.8 |
3.78/5.42 |
3.58/5.12 |
Max. Cooling Capacity (4) |
kW |
4.5 |
7.2 |
8.5 |
13 |
16 |
E.E.R (4) |
W/W |
2.7 |
2.8 |
2.9 |
2.96 |
2.85 |
Cooling Capacity Min./Max.(4) |
kW |
3.5/4.5 |
4.9/7.2 |
4.9 / 8.5 |
4.46/13 |
5.5/16 |
Cooling Power Input Min./Max.(4) |
W |
1.33/1.68 |
1451/2366 |
1358 / 2987 |
2592/4390 |
2970/5510 |
E.E.R Min./Max.(4) |
W/W |
2.5/2.74 |
2.8/3.1 |
2.6 / 3.5 |
2.96/3.29 |
2.85/3.2 |
Workable Ambient Temperature Range |
ºC |
-25~43 |
Min. System Water Temperature (Heating / Cooling) |
ºC |
20 / 7 |
Min. Floor Area for installation, operation and storage |
m2 |
9 |
22 |
28 |
56 |
58 |
Min. Area of Pipe-work |
m2 |
9 |
22 |
28 |
56 |
58 |
Max. Operation High Pressure |
MPa |
4.2 |
Max. Operation Low Pressure |
MPa |
1.2 |
Components |
|
|
|
|
|
|
|
Compressor |
Type - Quantity/System |
|
Twin Rotary - 1 |
Twin Rotary - 1 |
Twin Rotary - 1 |
Twin Rotary - 1 |
Twin Rotary - 1 |
Fan |
Quantity |
|
1 |
1 |
1 |
2 |
2 |
Airflow |
m3/h |
2500 |
3150 |
3150 |
6200 |
7000 |
Rated power |
W |
34 |
45 |
45 |
90 |
120 |
Noise Level (sound power) |
Indoor/Outdoor |
dB(A) |
44/52 |
44/53 |
44/52 |
44/59 |
44/61 |
Water Side Heat Exchanger |
Type |
|
Plate Heat Exchanger |
|
|
Water Pressure Drop |
kPa |
26 |
26 |
26 |
26 |
26 |
Piping Connection |
Inch |
G1" |
G1" |
G1" |
G1-1/4" |
G1-1/4" |
Hydraulics |
|
|
|
|
|
|
|
Allowable Water Flow |
Min./Rated./Max. |
L/S |
0.21/0.29/0.35 |
0.26/0.43/0.52 |
0.34/0.57/0.68 |
0.43/0.71/0.85 |
0.55/0.92/1.1 |
Dimensions and weight |
|
|
|
|
|
|
|
Net Dimension(L×D×H) |
Indoor Unit |
mm |
790x290x505 |
790x290x505 |
790x290x505 |
500x300x750 |
500x300x750 |
Outdoor Unit |
mm |
1010x370x700 |
1165x370x845 |
1165x370x845 |
1085x390x1450 |
1085x390x1450 |
Net Weight |
Indoor Unit |
Kg |
35 |
39 |
39 |
44 |
46 |
Outdoor Unit |
Kg |
63 |
75 |
79 |
120 |
130 |
|
|
|
|
|
|
|
|
Note: |
|
|
|
|
|
|
|
(1) Heating condition: water inlet/outlet temperature: 30ºC/35ºC, Ambient temperature: DB 7ºC/WB 6ºC; |
(2) Heating condition: water inlet/outlet temperature: 40ºC/45ºC, Ambient temperature: DB 7ºC/WB 6ºC; |
(3) Cooling condition: water inlet/outlet temperature: 23ºC/18ºC, Ambient temperature: DB 35ºC/WB 24ºC; |
(4) Cooling condition: water inlet/outlet temperature: 12ºC/7ºC, Ambient temperature: DB 35ºC/WB 24ºC; |
(5) The specifications are subject to change without prior notice. For actual specifications of unit, please refer to the stickers on the unit. |
AMITIME was set up in 2003, and is a professional manufacturer in China and a leading supplier of developing and providing energy saving products and cost-efficient solutions for European market.
AMITIME has established an effective and dynamic platform for development and manufacturing, and has reached strategic cooperation with ES, Parker Davis and other international heat pump and air conditioning companies. Through a wider European and global perspective, the joint cooperation has been very competitive and commercial successful to strengthen our leading position for overseas market.
AMITIME has worked in the R&D of air source heat pump with DC inverter compressor technologies for more than 18 years. As one of the pioneer developers of DC inverter heat pump, AMITIME has successfully launched four products series, including DC inverter air source heat pump, commercial inverter heat pump, swimming pool heat pump, fan coils.
AMITIME continually strives to meet customers' demands, and becomes very professional on providing OEM/ODM solution to our international distributors and partners, and keeps on delivering most competitive, high energy efficient, good quality and cost effective products for global market.